Smart switch, DIN rail mounted Shelly Qubino Wave PRO 1PM
Smart switch, DIN rail mounted Shelly Qubino Wave PRO 1PM
Short description
The device is a DIN rail mounted smart switch with power measurement. It controls the on/off function of a single electrical device with a load not exceeding 16 A. It is compatible with switches (by default) and push buttons.
The switch is connected to the input terminal SW (SW1)
If SW (SW1) is configured as a switch (by default), each switch toggle will change the state of output O (O1) to the opposite - on, off, on, etc.
-
To change the switch position once: Change the state of output O (O1) to the opposite state and send a command to the associated devices of groups 2 and 3 (see the "Z-Wave association" section).
-
Change the switch position twice: If the delay between the first and second press is less than 500 ms, it is interpreted as “Change the switch position twice”. Send the command to the associated devices (regulators, blinds,….) in the associated groups 2 and 3 (see the section "Z-Wave association").
The switch-monument is connected to the input terminal SW (SW1)
If SW (SW1) is configured as switch memory, then:
-
Switching to a closed switch-memory contact: Change the state of output state O (O1) to the on state and send a command to the associated devices of groups 2 and 3 (see the section "Z-Wave association")
-
Open switch memory contact: Change the state of output O (O1) to Off state and send a command to the associated devices of associated groups 2 and 3 (see section "Z-Wave Association")
Button connected to input terminal SW (SW1)
If SW (SW1) is configured as a button in the device settings, each press of the button changes the output state O (O1) to the opposite - on, off, on, etc.
-
1x click : Change the output state O (O1) to the opposite and send a command to the associated devices of groups 2 and 3 (see section "Z-Wave association")
-
2x click : if the delay between the first and second click is less than 500 ms, it is interpreted as a double click. Send the command to the associated devices (regulators, blinds,….) in the associated groups 2 and 3 (see section "Z-Wave Association")
-
Stop : sends a command to associated devices in associated group 3 (see section "Z-Wave association")
-
Release : sends a command to the associated devices of group 3 (see section "Z-Wave association")
Share