Shelly Qubino Wave PM Mini
Shelly Qubino Wave PM Mini
Short description
The device is a small-format smart electricity meter that allows you to remotely monitor the electricity consumption of electrical appliances with a load of up to 16 A.
Security features
Overheating protection
-
turns off its relay
-
sends a notification report to the gateway (overheating detected)
-
wired lights react as above (check the flashing mode when overheating is detected)
Each of the following actions clears this alarm: power cycle, short press of the S button, pressing any switch button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: Overheat protection is always active and cannot be disabled.
Additional description above in the Overheat Detection Notification section .
Overcurrent protection
The device has internal overcurrent protection. If the current exceeds 16 A + 10% (maximum switching current +10%) for more than 5 s, the device:
-
turns off its relay
-
sends a notification report to the gateway (overvoltage detected)
-
the LED lights respond as above (check the LED flashing pattern when overcurrent is detected)
Each of the following actions clears this alarm: power cycle, short press of the S button, pressing any switch/button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: Surge protection is always active and cannot be disabled.
Additional description above in section Notification of detected overvoltage .
Surge protection
The device has internal overvoltage protection. It is valid for a standard 230 V AC supply voltage. If the voltage exceeds 240 V AC + 15% (278 V AC) for more than 5 s, the device:
-
will turn off its relay
-
sends a notification report to the gateway (overvoltage detected)
-
the LED lights respond as above (check the LED flashing pattern when an overvoltage is detected)
Each of the following actions clears this alarm: power cycle, short press of the S button, pressing any switch/button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: Surge protection is always active and cannot be disabled.
Additional description above in section Notification of detected overvoltage .
Supported load types
-
Resistive (incandescent bulbs, heating devices)
-
Capacitor (capacitor batteries, electronic equipment, motor start capacitors)
-
Inductive with RC snubber (LED drivers, transformers, fans, refrigerators, air conditioners)
User interface
S button and operating modes
-
Normal mode
-
Setting in progress mode
-
Setting mode (S button)
-
The setup mode is required to start the desired procedure, for example: add (add), remove (remove), reset to factory settings, etc. Its operating time is limited. After completing the setup mode procedure, the device automatically switches to normal mode.
-
Entering setup mode:
-
Press and hold the S button on the device until the LED turns blue.
-
An additional quick press of the S button means changing the menu in an infinite loop
-
The menu LED status time is 10 s before returning to normal status.
-
-
S button functions
-
Manually Adding a Device to a Z-Wave Network
-
Manually Removing a Device from a Z-Wave Network
-
Factory reset the device
Share